B2426, B2427, B2428
Symptom: Fan control limited
Control voltage for ventilation fan, overload, shorted to ground or to Batt+
Fault symptom:
Fan control limited
Conditions
B2426: Control module output pin 20, overload.
B2427: Control module output pin 20, shorted to ground.
B2428: Control module output pin 20, shorted to battery positive
Diagnostic procedure
1.
|
Check fuse 12 and whether it is live.
|
2.
|
If diagnostic trouble code B1355 has been generated it should be dealt with first. Then clear the trouble codes. Continue fault diagnosis if they recur.
|
3.
|
Plug a BOB into the ACC control module and check the voltage on pins 37 and 20 as follows:
|
|
•
|
Full fan
pin 37 approx. 0 volts
pin 20 approx. 5 volts
|
|
•
|
No fan
pin 37 approx. 12 volts
pin 20 approx. 0 volts
The fan can be controlled by means of the buttons on the ACC panel or with the ISAT.
|
4.
|
Check the wiring between the pins indicated below for continuity/shorting
ACC control module pin
|
Connector H8-1 pin
|
37
|
6
|
20
|
8
|
17
|
5
|
|
5.
|
Change the fan control.
|
6.
|
Clear the diagnostic trouble codes. Continue with further measures as described in section