Anti-frost thermostat

Anti-frost thermostat


1. Plug in the scan tool and select "READ FAULT CODES" from the menu. If any trouble codes are present, continue on page .


2. With the engine running, select "ACT. OTHER FUNCT" from the scan tool menu and then "AC". The compressor should now be activated.


3. If it is not, check that a power supply of about 12 V is present on one of the anti- frost thermometer's connector contacts. If the voltage reading is OK, continue fault diagnosis as described in Service Manual 8:3 "Climate control system" .


4. If the voltage reading is not OK, connect a BOB and check the wiring for continuity/shorting between the ICE module and the anti-frost thermostat. NOTE: The scan tool command should still be activated.


5. If the wiring is OK, continue on .