SAAB WIS ONLINE

SELF-ARMING

SELF-ARMING

The theft alarm can be programmed for self-arming. This means that the alarm automatically starts monitoring without the use of the remote control. There are two types of self-arming. For both these alternatives, the time before the function becomes active should be specified. The so-called activating time should also be selected. The activating time is the time the 3 circuit breaking is active when the alarm has been set off.

When the alarm is set off, the selected country code will apply. The LED will start its delay period according to the specified "TIME BEFORE ACTIV." and then go over to indicating that the alarm is armed.

Programming

Self-arming

Connect the scan tool.

Select "PROGRAMMING"

Select "SELF-ARMING" and then:


1. "OFF" in order to deselect self- arming.

2. "AT +15 OFF" to select the self-arming function to be connected when the ignition is "OFF".

3. "+15 OFF DOOR CLOSED" to select the self-arming function to be connected with the ignition "OFF" and the driver door closed.


Time before self-arming




1. Select "TIME BEFORE ACTIV.".

2. Select time: 30, 60, 120, 180, 300 or 600 seconds as the time before the alarm self-arms.


Arming time

Select "ACTIVATION TIME": 30, 45 or 60 minutes.

Important

When self-arming has been selected, "self-immobilizing", or the so-called 3 circuit breaking will also be automatically included in the arming.