B1193
B1193 |
Horn, open-circuit
Fault symptom |
The horn does not work The LED flashes during the delay period
Conditions |
Open-circuit registers diagnostic trouble code
Action |
1. |
Check
fuse 23
|
2. |
Check to see if the horn works
Connect the ISAT scan tool. Select "ACTIVATE". Select "HORN". Select "ON". If the horn functions correctly, proceed to point 6. If not, proceed to point 3. |
3. |
Check the voltage supply to the
horn
Disconnect the horn. Connect the test lamp in the two 1 pin horn connectors. Repeat scan tool command as point 2. When "ON" is selected, the test lamp should light. If the test lamp lights, change the horn. If not, proceed to point 4. |
4. |
Check the horn +30
supply
Connect the test lamp between the 1 pin horn connector with the red lead and a safe grounding point. The test lamp should light. If the test lamp does not light, conduct a continuity test and take action on the cable assembly between the connector, pin 1 and fuse 23. If the test lamp lights, proceed to point 5. |
5. |
Check the horn grounding
Control module, pin 11 grounds the horn when it is activated. Conduct a continuity test on the cable assembly between the 1 pin horn connector, with the black lead and the control module, pin 11. The resistance should be < 1 Ohm. If the resistance is incorrect, take action on the fault in the cable assembly. If the resistance is correct, proceed to point 6. |