+30 supply
+30 supply |
Fault symptom |
The theft alarm is not working.
Important | ||
Loss of +30 supply to the control module leads to total loss of function. |
||
For US/CA, start fault diagnosis as point 1 |
||
For EU, start fault diagnosis as point 2. |
||
Action |
1. |
Check
fuse 23
Check fuse 23 and check that there is voltage to the fuse. Connect the test lamp between the fuse and a safe grounding point. The test lamp should light. If the test lamp lights, proceed to point 2. If the test lamp does not light, continue fault diagnosis in Service Manual 3:2 Electrical system, "+30 Power Supply". |
2. |
Check +30 supply
Unplug connector H33-3. Connect the test lamp between H33-3, pin 5 and a safe grounding point. The test lamp should light. If the lamp lights, proceed to point 4. If the test lamp does not light, proceed to point 3. |
3. |
Check the cable assembly to the
fuses
|
• |
UC/CA
Connect the test lamp between fuse 23 and a safe grounding point. The test lamp should light. If the test lamp lights, check and take action on the cable assembly between connector H33-3, pin 5 and fuse 23. If the test lamp does not light, continue fault diagnosis in Service Manual 3.2 Electrical System, "+30 Power Supply". |
• |
EU
Connect the test lamp between fuse 1 and a safe grounding point. The test lamp should light. If the test lamp lights, check and take action on the cable assembly between connector H33-3, pin 5 and fuse 1. If the test lamp does not light, continue fault diagnosis in Service Manual 3.2 Electrical System, "+30 Power Supply". |
4. |
Check the cable assembly to the control
module
Conduct a continuity test on the cable assembly between connector H33-3, pin 5 and the control module, pin 25. The resistance should be < 1 Ohm. If the resistance is incorrect, take action on the cable assembly. If the resistance is correct, proceed to point 5. |
5. |
Final test