Direction indicators light continuously. Direction indicators do not light.
Action |
2. |
Check the function of the direction indicators
using the ISAT scan tool.
Connect the scan tool. Select "ACTIVATE". Select "FLASHERS". Select "ON". The direction indicators should light continuously. If this does not work correctly, proceed to point 3. If this works correctly, the fault is intermittent. Proceed to point 4. |
3. |
Check the cable
assembly
Remove the alarm control module. Conduct a continuity test between: |
• |
control module pin 24 and connector, left-hand side
direction indicators.
|
• |
control module pin 12 and connector, right-hand side direction
indicators
|
• |
control module pin 24 or pin 12 and a safe grounding point. The resistance
should be < 1 Ohm. If the resistance is incorrect, take action on the cable assembly. If the
resistance is correct, proceed to point 4.
|
4. |
Final test
Check to see if the fault symptom remains. If the problem remains, proceed to . |