LED
LED |
Fault symptom |
LED does not light
Action |
1. |
Check to
see if the LED works
Connect the scan tool. Select "ACTIVATE". Select "LED" Select "ON". The LED should light. If the LED lights, the fault is intermittent. Proceed to point 6. If the LED does not light, proceed to point 2. |
2. |
Check if the LED is working
(contd.)
Disconnect the LED. Connect the test lamp in the 2 pin LED connector. Repeat the scan tool command as point 1. The test lamp should light. If the test lamp lights, change the LED. If the test lamp does not light, proceed to point 3. |
3. |
Check the voltage supply to the
LED
Unplug connector H33-1. Connect the test lamp between connector H33-1, pin 29 and a safe grounding point. Repeat the scan tool command as point 1. The test lamp should light. If the test lamp does not light, proceed to point 5. If the test lamp lights, proceed to point 4. |
4. |
Check the LED cable
assembly
Conduct a continuity test on the cable assembly between |
• |
connector H33-1, pin 29 and the 2 pin LED connector,
pin 2.
|
• |
the LED 2 pin connector, pin 1 and grounding point G34S.
The resistance should be < 1 Ohm. If the resistance is incorrect, take action on the cable assembly. If the resistance is correct, proceed to point 6. |
5. |
Check the cable assembly to the control
module
Conduct a continuity test on the cable assembly between connector H33-1, pin 29 and the control module, pin 2. The resistance should be < 1 Ohm. If the resistance is incorrect, take action on the fault in the cable assembly. If the resistance is correct, proceed to point 6. |
6. |
Final test
Check to see if the fault symptom remains. |