Electromagnet for gear position detent function
|
Electromagnet for gear position detent function
|
1.
|
Remove the floor and centre consoles, see Service Manual 8:2 "Interior equipment".
|
2.
|
Release the wiring by snipping the cable ties.
|
3.
|
Remove the electromagnet (2 screws).
|
1.
|
Slacken the electromagnet's screws.
|
2.
|
Measure the distance between the hook and pin when the hook is in its bottom position. The distance should be 1-2 mm.
|
4.
|
Fit the electromagnet and secure the wiring.
|
5.
|
Refit the floor and centre consoles, see Service Manual 8:2 "Interior equipment".
|