Fifth bow motor ratchet
Fifth bow motor ratchet |
To remove |
1. |
Operate the soft top so that the fifth bow and soft top cover are standing straight up.
![]() |
2. |
Remove the four ratchet retaining screws from the fifth bow.
|
3. |
Remove the two potentiometer retaining screws and cut off the cable tie. Carefully extract the potentiometer.
|
4. |
Remove the bolt going through the ratchet and lift out the ratchet.
|
To fit |

1. |
Put back the ratchet. Turn the link arm so that it comes behind the potentiometer mounting.
|
2. |
Fit the two bushings and the bolt.
|
3. |
Apply threadlocker on the potentiometer screws and fit the potentiometer. Secure the wiring with new cable ties.
![]() |
4. |
Apply threadlocker on the ratchet screws for the fifth bow. Fit the screws.
|
5. |
Connect the diagnostic tool, clear any diagnostic trouble codes and then program the control module. See
![]() |