CHECK ENGINE lamp (MIL) and SHIFT UPlamp
 
  
 
 
  
   
    
     |  | CHECK ENGINE lamp (MIL) and SHIFT UP
lamp | 
   
  
  
   
   
    
     Symptom of fault
    
   
   
    The lamps do not light up or are on constantly when not activated by the control
module.
    
    
   
   
    Note that the SHIFT UP lamp is tested for 3 seconds when the ignition is switched
on.
    
    
    
     Conditions
    
   
   
    No diagnostic trouble codes.
    
    
    
     Diagnostic procedure
    
    
     1. Check the lamps
    
    
      
    
    
   
   
  
    
  
  
  
  
   
    
     
      | - | Connect an ISAT scan tool. 
 
 | 
    
   
  
  
  
  
   
    
     
      | - | Ignition switch in ON position. 
 
 | 
    
   
  
  
  
  
   
  
  
  
  
   
    
     
      | - | Select "CHECK ENGINE LAMP"
and "SHIFT UP LAMP". 
 
 | 
    
   
  
  
  
   Each of the lamps should flash.
   
   
   
    Do the lamps flash?
   
   
   
    
     Functionality is OK.
     
     
    
   
   
   
   
    
     Check that the bulbs are in working order. Then continue with point 2.
     
     
    
   
   
   
    2. Check the wiring
   
   
     
   
   
  
  
  
   
    
     
      | - | Check the wiring between the
Trionic control module and the main instrument display panel. CHECK ENGINE lamp (MIL):
Between pin 32 of the Trionic control module and pin 22 of the main instrument display panel.
SHIFT UP lamp: Between pin 55 of the Trionic control module and pin 39 of the main
instrument display panel. 
 
 | 
    
   
  
  
  
   Is the wiring OK?
  
  
  
   
    Continue fault diagnosis as described in Service Manual 3:5 "Electrical
system, main instrument display panel".
    
    
   
  
  
  
  
   
    Rectify the fault.