ECM power supply
ECM power supply |

+30
Power (+30 circuit) is supplied from maxi fuse 2 to the main relay, fuel pump relay and fuse 28. Power is supplied to ECM pins 1 and 48 from fuse 28.The electronic control module uses the +30 power supply for its memory. The engine will not start unless power is supplied via the +30 circuit.
+15
Power (+15 circuit) is supplied to pin 60 of the Trionic electronic control module from fuse 17 via the anti-theft alarm's electronic control module. Applying power (+15 circuit) to pin 60 activates the electronic control module. The engine will not start unless power is supplied via the +15 circuit.