Test readings, control moduleconnections
| Test readings, control module connections | 
| Remember: | 
| • | Unless otherwise stated, all
voltage measurements should be carried out with all components connected and with the
ignition switch in the Drive position. | |
| • | Readings should be taken with a Breakout box (BOB) connected between the
SID unit and its connector. | |
| • | Several voltage levels should be regarded as guiding values. Use your common
sense when judging whether a particular reading is correct or not. | |
| • | If any reading is not OK, consult the wiring diagram to trace the leads,
connectors or components which ought to be checked more thoroughly. | |
| Pin | Colour | Component/function | In/Out | Test
conditions | Test
reading | Across X
Y | 
| 1 | GY/WH | Washer fluid level
sensor | In | Washer fluid present (closed) Washer
fluid not present (open) | 0 V 12 V | 1-20 | 
| 2 |  | Not used |  |  |  |  | 
| 3 | BK/GN | Coolant level sensor | In | Coolant present (closed) Coolant not
present (open) | 0 V 12 V | 3-20 | 
| 4 | BN | Filament monitor, front
lamps | In | OFF ON | 12 V 0 V | 4-20 | 
| 5 | PK | TSAS | In |  | Variable voltage 0-12 V | 5-20 | 
| 6 | RD | SENSONIC | In | Ignition ON Activate SID with Scan Tool
- No fault - Overheated clutch | 9-10 V LP HIp LOp 5-6 V LP HIp
LOp | 6-20 | 
| 7 |  | Not used |  |  |  |  | 
| 8 | BN/WH | ICE data | In | No message | about 8 V | 8-20 | 
| 9 | YE/GY | Ignition +15 | In | Ignition on | < 0.5 V | B+ -9 | 
| 10 |  | Not used |  |  |  |  | 
| 11 |  | Not used |  |  |  |  | 
| 12 | BU/GY | Bulb failure in main instrument display
panel 1 | Out | Lamp lit Lamp out | 0 V 12 V | 15-12 | 
| 13 | RD/WH | Washer fluid bulb in main instrument
display panel 1 | Out | Lamp lit Lamp out | 0 V 12 V | 13-15 | 
| 14 |  | Not used |  |  |  |  | 
| 15 | RD/WH | Ignition +30 | In |  | < 0.5 V | B+ -15 | 
| 16 | BN/OG | Bus + | In/Out | Ignition on | 2.5 V | 16-20 | 
| 17 | BU/OG | Bus - | In/Out | Ignition on | 2.5 V | 17-20 | 
| 18 | BU/GN | Outside temperature sensor
ground | In |  | 12 V | 15-18 | 
| 19 | YE/GN | Outside temperature
sensor | In | Ignition on | about 1.5-2.5 V at 20
°C | 19-20 | 
| 20 | BK | Signal ground | In | Ignition on | < 0.1 V | 20-batt- | 
| 21 |  | Not used |  |  |  |  | 
| 22 | VT/WH | Rheostat | In | Rheostat MIN @ HALF MIN
MAX | about 2 V about 12 V | 22-20 | 

 
     
		