ADJUSTMENT
ADJUSTMENT |
The following headings are displayed on the ISAT Scan Tool in the "ADJUSTMENT" menu.
1. |
"SPEEDOMETER"
|
2. |
"FUEL GAUGE"
|
3. |
"TURBO GAUGE"
|
4. |
"TEMPERATURE GAUGE"
|
5. |
|
1. |
"SPEEDOMETER"
With this command it is possible to ascertain the tyre size
for which the speedometer is programmed. The response consists of 2 figure groups, the first
is the number of pulses (from the ABS) which the speedometer interprets as one km and the
second is the number of pulses which the odometer interprets as one km. The figures should
coincide with those in the table below.
|
2. |
"FUEL GAUGE"
There are 2
parameters from which to choose. The first is used to move the entire tank scale up or
down.
Select a litres figure where the fuel gauge should show an empty tank. The range is between -10 and +10 litres in steps of 1 litre. The second parameter is "TANK DEAD RECKON" and you use this to choose the number of litres at which the main instrument switches from reading the tank transmitter to using fuel pulses to calculate the amount of fuel remaining in the tank. The range is between 0 and 20 litres in steps of 1 litre.
|
3. |
"TURBO GAUGE"
Adjustment of 2 turbo parameters "ATMOSPHERIC PRESS": Range between 81 and 120 kPa in steps of 3 kPa. The mark between the white and yellow zones. This is where you enter the turbo pressure the engine should have for the gauge needle to reach this mark. "MAX BOOST PRESSURE": Range between 150 and 231 kPa in steps of 3 kPa. This is where you enter the turbo pressure the engine should have for the gauge needle to reach the beginning of the red zone. |
4. |
"TEMPERATURE GAUGE"
Adjustment of 5 parameters "LOW TEMP UPPER": Range between 30 and 70°C (86 and 158°F) in steps of 1°C (1.8°F). The mark between the blue and white zones of the scale. "HORIZ. LOW TEMP": Range between 80 and 100°C (176 and 212°F) in steps of 1°C (1.8°F). This is the lowest temperature that the needle is allowed to indicate in the horizontal position. "HORIZ. HIGH TEMP": Range between 105 and 125°C (221 and 257°F) in steps of 1°C (1.8°F). This is the highest temperature that the needle is allowed to indicate in the horizontal position. "HIGH TEMP LOW": Range between 120 and 130°C (248 and 266°F) in steps of 1°C (1.8°F). The mark between the white and red zones of the scale. "BLACK PANEL TEMP": Range between 120 and 130°C (248 and 266°F) in steps of 1°C (1.8°F). This is the temperature at which the gauge lighting comes on when BLACK PANEL is activated.
|