SAAB WIS ONLINE

Electronic control module power supply and ground, anti-theft alarm

Electronic control module power supply and ground, anti-theft alarm



Electronic control module voltage supply


The +30 power supply goes via fuse 23 to pin 25 of the control module. The +30 circuit supplies power to all the control module functions except ignition (+15) and (+50).

The +15 power supply goes via fuse 17 to pin 10 of the control module.

The +50 power supply goes via fuse 36 to pin 20 of the control module.


Electronic control module ground

Electronic control module main ground (pin 13) is connected to grounding point G14.