Control module voltage feed
Control module voltage feed |
The control module is specified to work with a power supply between 7-16 volts.
Connector |
The control module connector is supplied with 5 short-circuiting jumpers that in pairs short-circuit the cables to the four electric detonators and between the warning lamp conductor and ground.
Diagnosis with diagnostic tool |