Pressure monitor
Pressure monitor |
To remove |
1. |
Remove the grille.
|
2. |
Drain the AC system of refrigerant.
|
3. |
Unplug the connector and unscrew the three-stage pressure switch (A).
![]() |
4. |
Hot-climate markets: Unplug the connector and unscrew the pressure switch (B).
|
5. |
Plug the openings in the AC system.
|
To fit |
![](/images/900/img-d8/d870r076.jpg)
1. |
Hot-climate markets: Lubricate a new O-ring (C) with synthetic vaseline and fit it in place on the receiver. Screw the pressure monitor (B) in place and plug in the connector.
|
2. |
Lubricate a new O-ring (D) with synthetic vaseline and fit it in place on the receiver. Screw the three-stage pressure switch (A) in place and plug in the connector.
|
3. |
Fill up with compressor oil, carry out vacuum pumping of the AC system and fill up with refrigerant.
|