Fifth bow motor ratchet
| Fifth bow motor ratchet |
| To remove |
| 1. |
Operate the soft top so that the fifth bow and soft top cover are standing straight up.
|
|
| 2. |
Remove the four ratchet retaining screws from the fifth bow.
|
|
| 3. |
Remove the two potentiometer retaining screws and cut off the cable tie. Carefully extract the potentiometer.
|
|
| 4. |
Remove the bolt going through the ratchet and lift out the ratchet.
|
|
| To fit |
| 1. |
Put back the ratchet. Turn the link arm so that it comes behind the potentiometer mounting.
|
|||||||
| 2. |
Fit the two bushings and the bolt.
|
||||||||||
| 3. |
Apply threadlocker on the potentiometer screws and fit the potentiometer. Secure the wiring with new cable ties.
|
|
| 4. |
Apply threadlocker on the ratchet screws for the fifth bow. Fit the screws.
|
|
| 5. |
Connect the diagnostic tool, clear any diagnostic trouble codes and then program the control module. See
.
|
|