Table for calculating potentiometer values
Table for calculating potentiometer values |
Make a copy of this table and use the copy to calculate the new potentiometer values.
Row
|
Position
|
Reading
|
Conversion factor
|
New value
|
A
|
Soft top, high limit "MAIN MOTOR HIGH LIMIT"
|
|
- 3 =
|
|
B
|
Soft top, overlap high limit "MAIN MOTOR OVERLAP HIGH LIMIT"
|
|
± 0 =
|
|
C
|
Soft top, overlap low limit "MAIN MOTOR OVERLAP LOW LIMIT"
|
B
(MAIN MOTOR OVERLAP HIGH LIMIT)
|
- 6 =
|
|
D
|
Soft top, low limit "MAIN MOTOR LOW LIMIT"
|
|
+ 1 =
|
|
E
|
Soft top cover, high limit "TONNEAU MOTOR HIGH LIMIT"
|
|
- 9 =
|
|
F
|
Soft top cover, overlap high limit "TONNEAU MOTOR OVERLAP HIGH LIMIT"
|
|
± 0
|
Fixed value
(*)
118
|
G
|
Soft top cover, overlap low limit "TONNEAU MOTOR OVERLAP LOW LIMIT"
|
|
± 0
|
Fixed value
(*)
112
|
H
|
Soft top cover, low limit "TONNEAU MOTOR LOW LIMIT"
|
|
+ 1 =
|
|
I
|
Fifth bow, high limit "#5 BOW MOTOR HIGH LIMIT"
|
|
- 2 =
|
|
J
|
Fifth bow, overlap high limit "#5 BOW MOTOR OVERLAP HIGH LIMIT"
|
K
(#5 BOW MOTOR OVERLAP LOW LIMIT)
|
+ 8 =
|
|
K
|
Fifth bow, overlap low limit "#5 BOW MOTOR OVERLAP LOW LIMIT"
|
|
± 0 =
|
|
L
|
Fifth bow, low limit "#5 BOW MOTOR LOW LIMIT"
|
|
± 0 =
|
|
(*) On cars with box B5 on the modification identity plate marked or with VIN S7013203 and higher, the soft top cover overlap position is fixed. Use the fixed values in the table.