Control module
Control module |
To ensure the best possible contact between the connections between potentiometers, microswitches and the "ROOF" button, the control module sends a burn-off current of 12V, 100 mA to burn off any impurities on the connections. This is done for 500 ms before the control module processor goes into a state of rest.
The control module has three connectors, one 42-pin denoted K42 and two 20-pin, denoted K20 (black) and K20W (white). The functions associated with each connector can be seen in the table "Test readings, control module connections".
In order to distinguish between the different connector pin numbers, the pin number will always be given together with the denomination of the control module connector.