Idle air control valve (IAC)
Idle air control valve (IAC) |
1. |
Remove the resonating
chamber.
|
2. |
Unplug the IAC valve's connector and remove the valve with
hoses.
|
3. |
Remove the valve from the bracket and
hoses.
|
To fit |
Fit in reverse order.
Important | ||
Note the arrow on the valve. It should point in the same direction as the air flow. |
||