SAAB WIS ONLINE

EVAP canister purge valve

EVAP canister purge valve


To remove


1. Unplug the connector from the purge valve. Note the position of the valve.


Note

Note the position of the valve.


1. Disconnect the hoses from the valve.

2. Remove the valve from the holder.


To fit

Fit in reverse order.

Pay attention to the position of the valve.

Important

Note the arrow on the valve. The arrow should point to the front.