CHECK ENGINE lamp (MIL) and SHIFT UPlamp
|
CHECK ENGINE lamp (MIL) and SHIFT UP
lamp
|
Symptom of fault
The lamps do not light up or are on constantly when not activated by the control
module.
Note that the SHIFT UP lamp is tested for 3 seconds when the ignition is switched
on.
Conditions
No diagnostic trouble codes.
Diagnostic procedure
1. Check the lamps
-
|
Connect an ISAT scan tool.
|
-
|
Ignition switch in ON position.
|
-
|
Select "CHECK ENGINE LAMP"
and "SHIFT UP LAMP".
|
Each of the lamps should flash.
Do the lamps flash?
Functionality is OK.
Check that the bulbs are in working order. Then continue with point 2.
2. Check the wiring
-
|
Check the wiring between the
Trionic control module and the main instrument display panel. CHECK ENGINE lamp (MIL):
Between pin 32 of the Trionic control module and pin 22 of the main instrument display panel.
SHIFT UP lamp: Between pin 55 of the Trionic control module and pin 39 of the main
instrument display panel.
|
Is the wiring OK?
Continue fault diagnosis as described in Service Manual 3:5 "Electrical
system, main instrument display panel".
Rectify the fault.