Charging system, general
Charging system, general |
1. |
Check the battery voltage on
generator 2.
|
2. |
Inspect fuse 17 and check that it is supplied with current.
|
3. |
Check that the charging lamp bulb is intact.
|
4. |
Check connectors and the wiring harness as well as the generator's
ground connection.
|
5. |
Check that terminal D+ on the generator is supplied with current.
|
6. |
Start the engine and take a voltage reading across B+ on the generator and
ground. Also take a voltage reading across D+ on the generator and ground. The difference
between the two readings obtained should not exceed 0.7 V.
|