Recirculation motor
| Recirculation motor | 
| To remove | 
| 1. | Remove the glove box. See Service Manual 8:2 "Interior equipment". | |
| 2. | Unplug the connector.   | |
| 3. | Remove the recirculation motor from the climate control unit housing by unhooking the locking tongues. | |
| 4. | Disconnect the motor shaft from the recirculation flap lever. If the shaft is in its bottom position, you will have to crack the link at the fracture notch with a screwdriver. | |
| 5. | Lift out the recirculation motor. | |
| To fit | 
 
   
   | 1. | Reconnect the shaft of the recirculation motor to the lever of the recirculation flap. | |
| 2. | Press the motor into the climate control unit housing. | |
| 3. | Plug in the connector. | |
| 4. | Refit the glove box. See Service Manual 8:2 "Interior equipment".   | |

 
     
		