B2413, B2414
B2413 , B2414 |
Conditions
B2413: Control module output pin 2 or 21, open circuit. B2414: Control module output pin 2 or 21, short circuit.Diagnostic procedure:
1. |
Unplug the recirculation motor's 2-pin connector. Plug the ISAT into the data link connector and issue the command "RECIRC.FLAP MOTOR" in the "ACTIVATE" menu. Read the voltage present at the connector as follows:
|
• |
Press "ON" on the ISAT and take a reading across pin 2 of the connector and ground.
|
• |
Press "OFF" and take a reading across pin 1 of the connector and ground.
In both cases the reading should be about 12 V. If it is, change the recirculation motor. |
2. |
Check the wiring for continuity/shorting as follows:
|
• |
across pin 21 of the ACC control module and pin 2 of the recirculation motor's connector.
|
• |
across pin 2 of the ACC control module and pin 1 of the recirculation motor's connector. Locate and rectify the open circuit/short circuit.
|
3. |
Go to section
for further measures.
|