SAAB WIS ONLINE

B1318, B1323 , B1328

Symptom: The soft top cannot be operated.

B1318 , B1323 , B1328

Potentiometer ( B1318 - Fifth bow, B1323 - Tonneau, B1328 - Main motor) shorted/open circuit.

Fault symptoms

The soft top cannot be operated.

Note

Diagnostic trouble code B1309 can also be generated when there is an open circuit on one of the potentiometers.


Conditions

These diagnostic trouble codes can be generated if there is an open circuit on the potentiometer input of the control module.

Diagnostic help

The position of the potentiometer can be read with the diagnostic tool.


- Connect the diagnostic tool.

- Turn the ignition switch to the ON position.

- Read the value for the relevant potentiometer


If everything is functioning correctly, the diagnostic tool should display the current potentiometer values, which should lie between 15 and 240 depending on the position of the soft top. The value 0 is displayed if there is an open circuit or short circuit.

If all the potentiometer values are incorrect, the fault is in the common supply to the potentiometers from control module pin 29 (K42) to crimp connection J32, or from pin 15 (K42) to crimp connector J117.

The voltage on the control module potentiometer feed measured against ground should be:

Pin 15.............5V.

Pin 29........... <0.1V.

Diagnostic procedure

1 Check the power supply to the potentiometer


- Unplug the potentiometer

- Turn the ignition switch to the ON position.

- Measure the voltage with a multimeter as follows:

between pin 1 and ground............approx. 5V

between pin 3 and ground.................< 0.1V


Are all the readings correct?

yes

Continue with step 2.


no

Check and, if necessary, rectify the relevant lead. Continue with step 3.


2. Check the control module input


- Connect the diagnostic tool.

- Turn the ignition switch to the ON position.

- Read the current potentiometer value.

- Connect a jumper lead in the connector as follows:

between pin 2 and pin 1

the diagnostic tool should display approx. 250

between pin 2 and pin 3

the diagnostic tool should display approx. 0


Are all the values correct?

yes

Change the potentiometer. Continue with step 3.


no

Check and if necessary rectify the relevant lead from the connector pin 2 to the potentiometer input on the control module. Continue with step 3.


3. Final check


- Clear the diagnostic trouble codes.

- Activate the soft top with the ROOF button and operate it for a few cycles

- Make sure the soft top is functioning correctly and that no diagnostic trouble codes are generated.


Has the diagnostic trouble code recurred?

yes

Change the control module as described in


no

The fault has been rectified.