Secondary air injection system
Secondary air injection system |
The secondary air injection system consists of an air injection pump which blows air into the exhaust manifold via a vacuum-controlled secondary air injection control valve (325) in the hose between the air injection pump and exhaust manifold. This valve obtains its control vacuum from the intake manifold.
The secondary air injection pump relay (324) is supplied with current (+30 circuit) when the control valve (584) relay is grounded via pin 19 of the control module.
The control valve relay is supplied with current (+15 circuit) via fuse 19.