"ACT. INSTR. FUNCT" command menu
| "ACT. INSTR. FUNCT" command menu | 
| Scan tool display | Function | 
| ACOUSTIC REMINDER ON/OFF | Activates sound (SOUND REMIND) in SID unit. | 
| DOOR INDIC. LAMP ON/OFF | Activates "Door open" indicator lamp in main instrument display panel. | 
| "REAR LIGHT FAILURE" ON/OFF | Activates message in SID unit. | 
| "BRAKE LAMP FAILURE" ON/OFF | Activates message in SID unit. | 
| "TEST BRAKE LIGHT" ON/OFF | Activates message in SID unit. | 
| SID OUTPUT ON/OFF | Causes SID unit output to go low (0 V) and high (12 V). | 
| SIM.COOL.TEMP 2 ON/OFF | Activates instrument needle of temperature gauge in main instrument display panel 2. | 
| SIM.COOL.TEMP 1 ON/OFF | Activates instrument needle of temperature gauge in main instrument display panel 1. | 
| TEMP.GAUGE OUT 2 ON/OFF | Causes output of main instrument display panel 2 to go low (0 V) and high (12 V). | 
| TEMP.GAUGE OUT 1 ON/OFF | Causes output of main instrument display panel 1 to go low (0 V) and high (12 V). | 

 
		