SAAB WIS ONLINE

B1213

Symptom: The lamp does not work or is on all the time.

B1213

Shorted to ground, open circuit

Fault symptom

The lamp does not work or is on all the time.




Conditions

B1213 : Seat-belt warning lamp shorted to battery positive, shorted to ground, open circuit.

NOTE: DTC B1213 will also be generated if the starter motor is run for lengthy periods.

Diagnostic procedure


1. Check the lamp in the dashboard.

Important

The seat-belt warning lamp lights up for only 6 seconds when the ignition is switched on. Check points 2 and 3 when the lamp is on. (The lamp can be switched on with the scan tool.)


2. Check that 12 V is present across pin 2 of the seat-belt warning lamp connector and a good ground. If it is not, check the lead between fuse 33 and the lamp.

3. Check that pin 1 of the lamp is connected to ground when activated.


4. If no ground connection is obtained, connect a BOB and check the lead between pin 56 of the ICE connector and pin 1 of the lamp connector for breaks/shorting.

5. Proceed to .