Power supply and grounding (MIU 2)
|
Power supply and grounding (MIU 2)
|
Power supply
When the ignition switch is in the Drive position, the main instrument display panel is supplied with current from the +30 circuit on pin 56 and from the +15 circuit on pin 55. The main instrument display panel is activated by the current from the +15 circuit.
Grounding
The main instrument display panel is grounded via pin 43. Grounding point G33S is located on the connector bracket below the left-hand A pillar in the cabin.