Horn
Symptom: Horn sounds continuously.
Fault symptom
Horn sounds continuously.
Diagnostic procedure
1 Check the horn
-
|
Connect the test lamp between the 1-pin horn connector, with the black lead, and Batt+.
|
Does the lamp light up?
Continue with point 2.
Change the horn.
2 Check the horn's ground connection
-
|
Check the continuity between the 1-pin horn connector, with the black lead, and the alarm control module, pin 11.
|
-
|
Also take a resistance reading across the connector and ground.
|
The resistance should be < 1 ohm.
Is the resistance correct?
Continue with point 3.
Repair or replace the wiring harness.
3 Final check
Check to see if the fault symptom remains.
Is the problem still present?
See "Before replacing a control module".
The remedial measures taken were correct or the fault is of intermittent nature.