Test readings, electronic control module connections, Anti-theft alarm with VSS
Test readings, electronic control module connections, Anti-theft alarm with VSS |
Pin
|
Component/Function
|
In/Out
|
Test conditions
|
Between
|
Test reading
|
Function/Fault diag.
|
1
|
Antenna,
Remote control unit, transmitter |
IN
|
Not measurable with conventional instruments
|
|
|
29/106
|
2
|
LED
|
OUT
|
Activate with ISAT scan tool
Select "LED". "OFF" "ON" |
2-13 2-13 |
<0.5 V 2 V |
27/94
|
3
|
Tailgate switch
|
IN
|
Tailgate closed Tailgate open
|
3-13
3-13 |
Batt+
0 V |
18/120
|
4
|
Door switches
|
IN
|
Door closed (switch open)
Door open (switch closed) |
4-13
4-13 |
Batt+
0 V |
18/98
|
5
|
Not used
|
|
|
|
|
|
6
|
Central locking system, unlocking
|
IN
|
Disarm the alarm using remote control, front doors
- normal position - unlock position Multimeter with min/max facility required. If min selected 0 V obtained. A conventional voltmeter drops from about 7 V to about 1.5-3 V. |
6-13
|
7 V 0 V for 0.75 sec |
32/98
|
7
|
Glass breakage sensor, input
|
IN
|
- normal position
- tap/scrape with bunch of keys |
7-13
|
0 V
2-4 V |
19/110
|
8
|
Not used
|
|
|
|
|
|
9
|
Immobilizing input
|
OUT
|
Ignition "ON"
Ignition "OFF", Ignition "OFF", key removed |
9-13
|
+B voltage +B voltage 0 V
|
26/150
|
10
|
+15
|
IN
|
Ignition "ON"
|
10-13
|
Batt+
|
22/146
|
11
|
Horn
|
OUT
|
Activate using ISAT scan tool Select "HORN" "OFF" "ON"
|
11-13 11-13
|
Batt+ 0 V
|
23/118
|
12
|
Direction indicators
|
OUT
|
Activate with ISAT scan tool
Select "FLASHERS" "OFF" "ON" |
12-13 12-13
|
0 V Batt+
|
24/114
|
13
|
Power ground
|
IN
|
|
13-Batt-
|
<0.1 V
|
15/--
|
14
|
Antenna ground
|
IN
|
Ignition "OFF"
|
14-13
|
<5 Ohm
|
29/106
|
15
|
Glass breakage sensor Cabriolet only
|
IN
|
Top down
|
15-13
|
|
|
16
|
Switch, hood
|
IN
|
Hood open Hood closed
|
16-13
|
0 V Batt+
|
18/102
|
17
|
Central locking system, locking
|
IN
|
Arm the alarm using remote control
- normal position - lock position Multimeter with min/max facility required. If min selected 0 V obtained. A conventional voltmeter drops from about 7 V to about 1.5-3 V. |
17-13
|
Batt+ 0 V for 0.75 sec |
31/98
|
18
|
Pictogram switch
|
IN
|
Door open (switch closed) Door closed (switch open)
|
18-13
|
0 V
Batt+ |
--/128
|
19
|
Diagnostics, comm. line
|
IN/OUT
|
ISAT scan tool connected ISAT scan tool not connected
|
19-13
|
Batt+
0 V |
39/158
|
20
|
Not used
|
|
|
|
|
|
21
|
+15 (4-cyl) +30 (6-cyl)
|
IN
|
Ignition "ON" (+15)
- ISAT scan tool connected - ISAT scan tool not connected |
21-13
|
11 V 4 V |
22/150
|
22
|
+30 supply direction indicators
|
IN
|
|
Batt+ -22
|
<0.5 V
|
15/154
|
23
|
Unlocking tailgate using remote control
|
IN
|
Activate with ISAT scan tool
Select "TAILGATE" "ON" "OFF" or remote control |
23-13 |
Batt+ 0 V |
33/124
|
24
|
Direction indicators
|
OUT
|
Activate with ISAT scan tool
Select "FLASHERS" "OFF" "ON" |
24-13 24-13 |
0 V Batt+ |
24/114
|
25
|
+30 supply control module
|
IN
|
|
Batt+ -25
|
<0.5 V
|
15/84
|