Test readings, electronic control module connections, Anti-theft alarm with VSS
| Test readings, electronic control module connections, Anti-theft alarm with VSS | 
| Pin | Component/Function | In/Out | Test conditions | Between | Test reading | Function/Fault diag. | 
| 1 | Antenna, Remote control unit, transmitter | IN | Not measurable with conventional instruments |  |  | 29/106 | 
| 2 | LED | OUT | Activate with ISAT scan tool Select "LED". "OFF" "ON" | 2-13 2-13 | <0.5 V 2 V | 27/94 | 
| 3 | Tailgate switch | IN | Tailgate closed Tailgate open | 3-13 3-13 | Batt+ 0 V | 18/120 | 
| 4 | Door switches | IN | Door closed (switch open) Door open (switch closed) | 4-13 4-13 | Batt+ 0 V | 18/98 | 
| 5 | Not used |  |  |  |  |  | 
| 6 | Central locking system, unlocking | IN | Disarm the alarm using remote control, front doors - normal position - unlock position Multimeter with min/max facility required. If min selected 0 V obtained. A conventional voltmeter drops from about 7 V to about 1.5-3 V. | 6-13 | 7 V 0 V for 0.75 sec | 32/98 | 
| 7 | Glass breakage sensor, input | IN | - normal position - tap/scrape with bunch of keys | 7-13 | 0 V 2-4 V | 19/110 | 
| 8 | Not used |  |  |  |  |  | 
| 9 | Immobilizing input | OUT | Ignition "ON" Ignition "OFF", Ignition "OFF", key removed | 9-13 | +B voltage +B voltage 0 V | 26/150 | 
| 10 | +15 | IN | Ignition "ON" | 10-13 | Batt+ | 22/146 | 
| 11 | Horn | OUT | Activate using ISAT scan tool Select "HORN" "OFF" "ON" | 11-13 11-13 | Batt+ 0 V | 23/118 | 
| 12 | Direction indicators | OUT | Activate with ISAT scan tool Select "FLASHERS" "OFF" "ON" | 12-13 12-13 | 0 V Batt+ | 24/114 | 
| 13 | Power ground | IN |  | 13-Batt- | <0.1 V | 15/-- | 
| 14 | Antenna ground | IN | Ignition "OFF" | 14-13 | <5 Ohm | 29/106 | 
| 15 | Glass breakage sensor Cabriolet only | IN | Top down | 15-13 |  |  | 
| 16 | Switch, hood | IN | Hood open Hood closed | 16-13 | 0 V Batt+ | 18/102 | 
| 17 | Central locking system, locking | IN | Arm the alarm using remote control - normal position - lock position Multimeter with min/max facility required. If min selected 0 V obtained. A conventional voltmeter drops from about 7 V to about 1.5-3 V. | 17-13 | Batt+ 0 V for 0.75 sec | 31/98 | 
| 18 | Pictogram switch | IN | Door open (switch closed) Door closed (switch open) | 18-13 | 0 V Batt+ | --/128 | 
| 19 | Diagnostics, comm. line | IN/OUT | ISAT scan tool connected ISAT scan tool not connected | 19-13 | Batt+ 0 V | 39/158 | 
| 20 | Not used |  |  |  |  |  | 
| 21 | +15 (4-cyl) +30 (6-cyl) | IN | Ignition "ON" (+15) - ISAT scan tool connected - ISAT scan tool not connected | 21-13 | 11 V 4 V | 22/150 | 
| 22 | +30 supply direction indicators | IN |  | Batt+ -22 | <0.5 V | 15/154 | 
| 23 | Unlocking tailgate using remote control | IN | Activate with ISAT scan tool Select "TAILGATE" "ON" "OFF" or remote control | 23-13 | Batt+ 0 V | 33/124 | 
| 24 | Direction indicators | OUT | Activate with ISAT scan tool Select "FLASHERS" "OFF" "ON" | 24-13 24-13 | 0 V Batt+ | 24/114 | 
| 25 | +30 supply control module | IN |  | Batt+ -25 | <0.5 V | 15/84 | 

 
		