Power supply +X
Power supply +X |
Description of operation |
Positive voltage is fed to ignition switch 20 via Maxi fuse 3 and crimp J1.
When the ignition switch is turned to any other position than OFF, the 30 and X connections in the ignition switch will be connected together.
+X voltage is fed via crimp J163 to:
• |
Fuse board 22a
|
- |
fuses 9 and 11
|
• |
Light switch 10
|
When the light switch is set to position 2, current will be supplied to:
• |
Fuse board 22a
|
- |
fuses 29 and 30
|
• |
Lighting relay 8
|