Power supply +30 page 2 LHD
|
Power supply +30 page 2 LHD
|
Description of operation/list of components page 2 LHD
|
The following components are supplied via maxi fuse 1 in maxi fuse box 501 and crimp J89:
|
-
|
fuses 1, 4, 13, 23, 25, 33 and 34
|
Via maxi fuse 2 in maxi fuse board 501
A. to Rev.1
the following components are supplied via crimp J2:
•
|
Crimp J93 which in turn supplies
|
|
-
|
fuses 2, 12, 28 in fuse board 22a
|
|
-
|
relay contact in fuel pump relay 102
|
|
-
|
relay contact and coil in injector relay 229
|
|
-
|
Crimp connector JH3, which in turn supplies
fuses 5, 10, 16 in fuse board 22a
|
B. from Rev.1 inclusive
the following components are supplied via crimp J93:
•
|
relay contact in fuel pump relay 102
|
•
|
relay contact and coil in injector relay 229
|
•
|
Crimp connector JH3, which in turn supplies
|
|
-
|
fuses 5, 10, 16 in fuse board 22a
|
•
|
Crimp J2, which in turn supplies
|
|
-
|
fuses 2,12, 27, 28 and 35 in fuse board 22a
|
The following components are supplied via maxi fuse 3 in maxi fuse box 501 and crimp J1:
The following components are supplied via Maxi fuse 4 in maxi fuse box 501:
•
|
Relay contacts in ignition switch relay 21
|
The following components are supplied via Maxi fuse 5 in maxi fuse box 501:
•
|
TSAS control module 565
|