SAAB WIS ONLINE

B2426, B2427, B2428

Symptom: Fan control limited

B2426 , B2427 , B2428

Control voltage for ventilation fan, overload, shorted to ground or to Batt+



Fault symptom:

Fan control limited

Conditions

B2426: Control module output pin 20, overload.

B2427: Control module output pin 20, shorted to ground.

B2428: Control module output pin 20, shorted to battery positive

Diagnostic procedure


1. Check fuse 12 and whether it is live.

2. If diagnostic trouble code B1355 has been generated it should be dealt with first. Then clear the trouble codes. Continue fault diagnosis if they recur.


3. Plug a BOB into the ACC control module and check the voltage on pins 37 and 20 as follows:


Full fan

pin 37 approx. 0 volts

pin 20 approx. 5 volts

No fan

pin 37 approx. 12 volts

pin 20 approx. 0 volts

The fan can be controlled by means of the buttons on the ACC panel or with the ISAT.

4. Check the wiring between the pins indicated below for continuity/shorting


ACC control module pin

Connector H8-1 pin

37

6

20

8

17

5



5. Change the fan control.

6. Clear the diagnostic trouble codes. Continue with further measures as described in section if the diagnostic trouble codes recur.