Test data, control module connections
|
Test data, control module connections
|
Unless otherwise specified, the ignition should be switched ON. All data are approximate.
Pin
|
Component/Function
|
In/Out
|
Test condition
|
Test reading
|
Across X-Y
|
Signal, see page
|
1
|
Ground
|
In
|
|
< 0.4 V
|
1 - B neg
|
lyyly
|
2
|
Recirculation motor (F)
|
Out
|
Activate with ISAT: ON ;0.5q> Activate with ISAT: OFF
|
Batt+ 1 V ;0.5q> 0 V
|
2 - 1
|
|
3
|
Parking heater
|
In
|
Parking heater off
Parking heater on
|
Batt+
Batt+
|
22-3
3-1
|
|
4
|
+54 supply
|
In
|
Ignition OFF
|
<0.5 V
Batt+
|
Batt+ - 4
|
|
5
|
Not used
|
|
|
|
|
|
6
|
Not used
|
|
|
|
|
|
7
|
Not used
|
|
|
|
|
|
8
|
Air blending flap motor
|
Out
|
Stationary flap motor
|
approx. 1 V
|
8-1
|
|
9
|
Not used
|
|
|
|
|
|
10
|
Not used
|
|
|
|
|
|
11
|
SI-BUS(+)
|
In/Out
|
|
approx. 2.5 V
|
11-1
|
|
12
|
Not used
|
|
|
|
|
|
13
|
SI-BUS(-)
|
In/Out
|
|
approx. 2.5 V
|
13-1
|
|
14
|
Blended air sensor, ground
|
Out
|
|
< 0.1 V
|
14-1
|
|
15
|
Cabin temperature sensor, ground
|
Out
|
|
< 0.1 V
|
15-1
|
|
16
|
Power supply, cabin temperature fan
|
Out
|
|
Batt+
|
16-1
|
|
17
|
Power supply, fan control
|
Out
|
|
Batt+
|
17-1
|
|
18
|
Not used
|
|
|
|
|
|
19
|
Not used
|
|
|
|
|
|
20
|
Control voltage, fan
|
Out
|
No fan
Full fan
|
0 V
5 V
|
20-1
|
|
21
|
Recirculation motor (R)
|
Out
|
Activate "ON" with ISAT
Activate "OFF" with ISAT
|
0 V
BATT+ -1 V
|
21-1
|
|
22
|
+30 supply
|
In
|
|
< 0.5 V
|
B+ 22
|
|
23
|
Air distribution flap motor
|
Out
|
Stationary flap motor
|
Batt+ 1 V
|
23-1
|
|
24
|
Air distribution flap motor
|
Out
|
Stationary flap motor
|
approx. 1 V
|
24-1
|
|
25
|
Air distribution flap motor
|
Out
|
Stationary flap motor
|
Batt+ 1 V
|
25-1
|
|
26
|
Air distribution flap motor
|
Out
|
Stationary flap motor
|
approx. 1 V
|
26-1
|
|
27
|
Air blending flap motor
|
Out
|
Stationary flap motor
|
Batt+ 1 V
|
27-1
|
|
28
|
Air blending flap motor
|
Out
|
Stationary flap motor
|
Batt+ 1 V
|
28-1
|
|
29
|
Air blending flap motor
|
Out
|
Stationary flap motor
|
approx. 1 V
|
29-1
|
|
30
|
Rheostat
|
In
|
Max. rheostat
|
Batt+
|
30-1
|
|
31
|
Electrically heated rear window
|
In
|
Heated rear window on
Heated rear window off
|
0 V
Batt+
|
31-1
|
|
32
|
Blended-air sensor
|
In
|
At approx. +23
°
C
|
approx. 2.5 V
|
32-1
|
|
33
|
Cabin temperature sensor
|
In
|
At approx. +20
°
C
|
approx. 2.7 V
|
33-1
|
|
34
|
Solar sensor
|
In
|
Illuminate with light bulb
|
0-0.5 V
|
34-1
|
|
35
|
Solar sensor ground
|
Out
|
|
< 0.1 V
|
35-1
|
|
36
|
Not used
|
|
|
|
|
|
37
|
Test voltage, fan
|
In
|
Full fan
No fan
|
0 V
Batt+
|
37-1
|
|
38
|
AC (to ICE)
|
Out
|
AUTO MODE
ECON MODE
|
Batt+
0 V
|
38-1
|
|
39
|
Electrically heated rear window
|
Out
|
Heated rear window ON (use test diode)
Heated rear window off
|
Diode flashes
|
|
|