It breaks the electric circuit to the compressor if the pressure rises above 30 bar. When the pressure has fallen to about 24 bar, the compressor is reconnected.
An additional pressure monitor is fitted on cars for hot-climate countries. It starts the second stage of the ventilation fan when the pressure in the AC system exceeds 22 bar. The service connection for the high-pressure side is also fitted on the receiver.
When you are working on the AC system it is important to plug all connections which have been opened in order to prevent the receiver from sucking in moisture from the air. If the AC system has been open for more than 15 minutes altogether, fit a new receiver. It will then have absorbed so much moisture that it cannot operate any longer. A new receiver should also be fitted if there has been a break in a hose or a major leakage. If minor leakage has occurred, such as in a hose connection, it will not be necessary to fit a new receiver.
|