SAAB WIS ONLINE

Fifth bow latch motor from VIN V7010306

Fifth bow latch motor from VIN V7010306

To remove


1. Operate the soft top so that the fifth bow and soft top cover are completely raised.


2. Connect the diagnostic tool and operate the fifth bow latch motor to half open position (the rotating covers on the soft top cover are in half open position) with the diagnostic tool command:

“TSAS”

“ACTIVATE”

“#5 BOW LATCH MOTOR”

“UP”

Important

This function cannot be performed unless the control module has previously been changed in accordance with SI 812-1566.


3. Protect the rear wings and boot lid with covers. Tuck the cover under the soft top cover as the motor can easily fall on the boot lid.

4. Remove the cover.


5. Detach the control rods from the fifth bow latch motor.


6. Remove the screws securing the motor.

7. Unplug the electric connections and lift away the motor.


To fit



1. Put the latch motor in place and tighten the screws. The end sleeves on each crash wire must be facing each other.

Tightening torque for the crash wire fittings: 14 Nm (10.3 lbf ft)

2. Put the control rods in place on the motor.

3. Plug in the connector.

4. Put back the cover.


5. Adjust the latch function. See .

6. Connect the diagnostic tool and clear any diagnostic trouble codes.