Fifth bow potentiometer
Fifth bow potentiometer |
To remove |
1. |
Remove the side trim. See
.
|
2. |
The fifth bow and soft top cover must be in a raised position.
|
3. |
Remove the cover.
|
4. |
Remove the potentiometer retaining screws.
|
5. |
Cut off the cable ties.
|
6. |
Unplug the electric connection, pull out the wires and lift out the potentiometer.
|
To fit |
1. |
Put the potentiometer in place and position the wiring.
|
2. |
Tighten the potentiometer retaining screws.
|
3. |
Connect the wiring and secure it with a cable tie so that is will not be damaged when the soft top is operated.
|
4. |
Put back the cover. Adjust as necessary. See
.
|
5. |
Put back the side trim. See
|
6. |
Connect the diagnostic tool, clear any diagnostic trouble codes and then program the control module. See
.
|