Test readings, control module connections
 
  
 
 
  
   
    
     |  | Test readings, control module connections | 
   
  
  
  
   The following pages contain values and instructions for obtaining readings of signals and levels on the control module.
   
   
   
   
   
   
   
  
  
   
  
  
  
   
    
     
      | • | Note the test conditions and use your common sense when judging the test results. 
 
 | 
    
   
  
  
   
    
     
      | • | First check that the control module is supplied with current and grounded. 
 
 | 
    
   
  
  
   
    
     
      | • | Then check all sensor inputs and signals from other systems. 
 
 | 
    
   
  
  
   
    
     
      | • | Check the control module outputs last. Remember that the test readings do not indicate whether or not the actuator is working. 
 
 | 
    
   
  
  
   
    
     
      | • | If any reading is not OK, consult the wiring diagram to trace the leads, connectors or components which ought to be checked more thoroughly. 
 
   
 | 
    
   
  
  
   
    
     
      | • | The test readings given apply to a correctly calibrated Fluke 88/97. 
 
 | 
    
   
  
  
   
    
     
      | • | The readings indicate the pulse ratio and pulse duration of the signal. A test instrument capable of measuring both pulse ratio and pulse duration must be used. The + sign denotes a positive trigger pulse (TRIG+). 
 
 | 
    
   
  
  
  
   
   
   
     
   
   
   
    
     
     
     
     
     
     
    
    
     
      | Pin | Component/Function | In/Out | Test conditions | Between X and Y | Measurement value (V) | 
     
      | 1 
 
 | Power supply +30 
 
 | In 
 
 | 
 
 | 1-8 
 
 | B+ 
 
 | 
     
      | 2 
 
 | Power supply (+15 circuit) 
 
 | In 
 
 | Ignition ON 
 
 | 2-8 
 
 | B+ 
 
 | 
     
      | 3 
 
 | Switch, downward angling 
 
 | In 
 
 | Ignition ON 
 Button in neutral
 
 Button pressed in
 
 
 | 3-8 
 
 | 
 B+
 
 < 0,5
 
 
 | 
     
      | 4 
 
 | Power supply, potentiometers, left door 
 
 | Out 
 
 | Ignition ON 
 
 | 4-8 
 
 | 4-6 
 
 | 
     
      | 5 
 
 | Power supply, potentiometers, right door 
 
 | Out 
 
 | Ignition ON 
 
 | 5-8 
 
 | 4-6 
 
 | 
     
      | 6 
 
 | Ground, potentiometers, left door 
 
 | In 
 
 | Ignition ON 
 
 | 6-fuse grounding point 
 
 | < 0,5 
 
 | 
     
      | 7 
 
 | Ground, potentiometers, right door 
 
 | In 
 
 | Ignition ON 
 
 | 7-fuse grounding point 
 
 | < 0,5 
 
 | 
     
      | 8 
 
 | Ground 
 
 | In 
 
 | 
 
 | 8-fuse grounding point 
 
 | < 0,5 
 
 | 
     
      | 9 
 
 | Potentiometer, horizontel, left door 
 
 | Out 
 
 | Ignition ON 
 
 | 9-7 
 
 | 0,5-4,5 
 
 | 
     
      | 10 
 
 | Potentiometer, horizontel, right door 
 
 | In 
 
 | Ignition ON 
 
 | 10-7 
 
 | 0,5-4,5 
 
 | 
     
      | 11 
 
 | Potentiometer, vertical, right door 
 
 | In 
 
 | Ignition ON 
 
 | 11-7 
 
 | 0,5-4,5 
 
 | 
     
      | 12 
 
 | Potentiometer, vertical, left door 
 
 | In 
 
 | Ignition ON 
 
 | 12-7 
 
 | 0,5-4,5 
 
 | 
     
      | 13 
 
 | Motor, vertical, right door 
 
 | Out 
 
 | Ignition ON 
 See table
   
 
 | 13-7 
 
 | B+ 
 < 0,5
 
 
 | 
     
      | 14 
 
 | Motor, horizontal, right door 
 
 | Out 
 
 | Ignition ON 
 See table
   
 
 | 14-7 
 
 | B+ 
 < 0,5
 
 
 | 
     
      | 15 
 
 | Motor, horizontel, left door 
 
 | Out 
 
 | Ignition ON 
 See table
   
 
 | 15-7 
 
 | B+ 
 < 0,5
 
 
 | 
     
      | 16 
 
 | Motor, vertical, left door 
 
 | Out 
 
 | Ignition ON 
 See table
   
 
 | 16-7 
 
 | B+ 
 < 0,5
 
 
 | 
     
      | 17 
 
 | Motor, common output 
 
 | Out 
 
 | Ignition ON 
 See table
   
 
 | 17-7 
 
 | B+ 
 < 0,5
 
 
 | 
     
      | 18 
 
 | No connection 
 
 | 
 
 | 
 
 | 
 
 | 
 
 | 
     
      | 19 
 
 | I-Bus (+) 
 
 | In/Out 
 
 | Ignition ON 
 
 | 19-8 
 
 | 2-3 
 
 | 
     
      | 20 
 
 | I-Bus (-) 
 
 | In/Out 
 
 | Ignition ON 
 
 | 20-8 
 
 | 2-3 
 
 |