Fuel Pump Flow Control Module Programming and Setup |
1. |
The battery is fully charged. |
2. |
The MDI data link connectors are secure. |
3. |
The scan tool is loaded with the most current software version. |
4. |
All disconnected modules and devices are reconnected securely. |
5. |
This entire procedure has been reviewed before proceeding. |
Fuel Pump Control Module Programming |
1. |
With a scan tool, access Service Programming System (SPS) and follow the on-screen instructions. Refer to Service Programming System (SPS). |
2. |
On the SPS Supported Controllers screen, select CCM Fuel Pump Flow Control Module - Programming and follow the on-screen instructions. |
Note | ||
After programming is completed, perform the following to avoid future misdiagnosis: | ||
1. |
Turn the ignition OFF, for 10 seconds. | |
2. |
Open and close the door. | |
3. |
Connect the scan tool to the data link connector. | |
4. |
Ignition ON, with the engine OFF | |
5. |
With a scan tool, clear all DTC"s from all modules. |