Delphi Connectors (Pull To Seat) |
Terminal Removal Procedure |
1. |
Remove the connector position assurance (CPA) device and/or the secondary lock. |
2. |
Disconnect the connector from the component or separate the connectors for in-line connectors. |
3. |
Remove the terminal position assurance (TPA) device. |
4. |
Review the connector end view to determine the proper test probe and release tool. |
5. |
Insert the release tool into the front of the connector body. |
6. |
Grasp the wire at the back of the connector body and gently push the terminal out the front of the connector body. |
7. |
Repair the terminal by following the Repairing Connector Terminals procedure. |
8. |
Insert the repaired terminal back into the cavity. Repeat the diagnostic procedure to verify the repair and reconnect the connector bodies. |
Terminal Insertion Procedure |
1. |
Align the terminal and pull the wire from the back of the connector in order to seat the terminal. |
2. |
If the connector is outside of the passenger compartment, apply dielectric grease to the connector. |
3. |
Install the TPA, CPA, and/or the secondary locks. |