Tyco/AMP Connectors (Seat) |
• |
EL-38125-580 Terminal Release Tool Kit
|
• |
J-38125-11A Terminal Release Tool
|
• |
J-38125-212 Terminal Release Tool
|
• |
J-38125-556 Terminal Release Tool
|
• |
J-38125-560 Terminal Release Tool
|
Terminal Removal Procedure |
1. |
Grasp the locking slide lever and pull outward from the end of the connector. |
2. |
As the slide lever is pulled out the mating connector is lifted from the seated position. |
3. |
Using terminal release tool J-38125-11A or equivalent, push the TPA tabs into the connector body. |
4. |
Pull the TPA from the connector body. |
5. |
Using terminal release tool J-38125-11A or equivalent, release the connector wire dress cover locking tab. |
6. |
With the lock tab released, lift the connector wire dress cover from the connector body. |
7. |
Using terminal release tool J-38125-212, press the prongs into the holes each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body. |
8. |
Using terminal release tool J-38125-560, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body. |
9. |
Using terminal release tool J-38125-556, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body. |
10. |
Repair the terminal by following the Repairing Connector Terminals procedure. |
11. |
Insert the repaired terminal back into the cavity. Repeat the diagnostic procedure to verify the repair and reconnect the connector bodies. |