Yazaki Connectors (16-Way) |
• |
EL-38125-580 Terminal Release Tool Kit
|
• |
J-38125-215 Terminal Release Tool
|
Terminal Removal Procedure |
1. |
While depressing the lock, pull the two connector halves apart. |
2. |
Use a small flat-blade tool to very carefully push the TPA towards the face of the connector on both sides of the connector. |
3. |
View of the male half of the connector with female terminals. |
4. |
View of the female half of the connector with male terminals. |
5. |
Use the J-38125-215 tool to release the terminals by inserting the tool into the terminal release cavity. |
6. |
View of the female half of the connector with male terminals. |
7. |
View of the male half of the connector with female terminals. |
8. |
While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector. |
9. |
Repair the terminal by following the Repairing Connector Terminals procedure. |
10. |
Insert the repaired terminal back into the cavity. Repeat the diagnostic procedure to verify the repair and reconnect the connector bodies. |