Overpressure valve, compressor, To remove and To fit, Z18XE
Overpressure valve, compressor, To remove and To fit, Z18XE |
To remove |
1. |
Air conditioning, draining
see method description Draining and filling the refrigerant . |
3. |
Remove the compressor's pressure relief valve:
- Unscrew the compressor pressure relief valve (3) |
To fit |
1. |
Fit the compressor's pressure relief valve:
- Use a new sealing ring Instructions: Moisten the sealing ring with mineral oil (part no. 90 001 8100, catalogue no. 19 49 870) before fitting. - Tighten the compressor's pressure relief valve (10 Nm) |
2. |
Fit the refrigerant line as follows:
- Change the seal (2) - Attach the refrigerant line (1) - Tighten the bolt (20 Nm) |
3. |
Air conditioning, draining and filling
see method description Draining and filling the refrigerant . |