Activation unit, roll bar (734D, 734P)
|
Activation unit, roll bar (734D, 734P)
|
Warning
|
|
|
|
|
Warning
|
The roll bar activation unit can only be replaced 9 times. When it has been replaced 9 times the complete roll bar must be replaced. To guarantee the correct number of activation unit replacements the following label must be fitted on the roll bar unit.
|
|
|
|
|
Warning
|
The battery's ground cable must be removed before the positive cable. Wait for at least 1 minute after disconnecting the battery before beginning any work on the airbag system. Otherwise the airbag may be deployed unintentionally and this can cause fatal/severe personal injuries.
|
|
|
|
|
1.
|
Turn the ignition key to the position LOCK.
|
3.
|
Remove the speaker or cover.
|
4.
|
Check the number of labels on the roll bar unit. If 9 labels are fitted then the entire roll bar unit must be replaced, see
Roll bar unit.
Warning
|
The roll bar activation unit can only be replaced 9 times. When it has been replaced 9 times the complete roll bar must be replaced. To guarantee the correct number of activation unit replacements the following label must be fitted on the roll bar unit.
|
|
|
|
|
|
5.
|
Carefully release the protective tape around the connector.
|
6.
|
Remove the connector from the activation unit.
|
7.
|
Remove the screws and flanges holding the activation unit.
|
8.
|
Remove the activation unit from the roll bar unit.
|
1.
|
Place the activation unit in the assembly position on the roll bar unit.
Important
|
Ensure that the recess on the element fits the control lugs on the roll bar unit.
|
|
|
2.
|
Fit the flange and screws.
|
3.
|
Attach the connector to the activation unit.
|
4.
|
Refit the protective tape.
|
5.
|
Fit the enclosed labels on the back of the roll bar unit.
|
6.
|
Fit the speaker or cover.
|
9.
|
Turn ON the ignition and check the airbag system and control module using the diagnostic tool as follows:
Connect the diagnostics instrument to the diagnostics socket under the dashboard. Delete any trouble codes.
Switch off the ignition and then on again. Wait at least 1 minute with the ignition switched on.
Check whether a diagnostic trouble code is displayed:
If a diagnostic trouble code is displayed:
Carry out fault diagnosis according to the instructions under respective trouble codes.
If no diagnostic trouble code is displayed:
Fitting completed correctly. Disconnect the diagnostics instrument.
|