SAAB WIS ONLINE

Primary Fuel Level Sensor Replacement

Primary Fuel Level Sensor Replacement

Removal Procedure

Warning

Fuel Vapors can collect while servicing fuel system parts in enclosed areas such as a trunk. To reduce the risk of fire and increased exposure to vapors:

Use forced air ventilation such as a fan set outside of the trunk.

Plug or cap any fuel system openings in order to reduce fuel vapor formation.

Clean up any spilled fuel immediately.

Avoid sparks and any source of ignition.

Use signs to alert others in the work area that fuel system work is in process.



1. Remove the primary fuel tank module. Refer to Primary Fuel Tank Module Replacement (NA3, NE9, NF9) Primary Fuel Tank Module Replacement (NT7, NU5) .


2. Using two flat-bladed tools, carefully pull both locking tabs (1) outward while simultaneously lifting the level sensor.

3. Using a small, flat-bladed tool, release the retaining tabs (1) while simultaneously pulling the electrical terminals out of the housing.



Installation Procedure


1. Push in the electrical terminals (1) and ensure the terminals are secure.


2. Carefully insert the level sensor until the locking tabs (1) snap into the locking position.


3. Install the primary fuel tank module. Refer to Primary Fuel Tank Module Replacement (NA3, NE9, NF9) Primary Fuel Tank Module Replacement (NT7, NU5) .