Battery Positive and Negative Cable Replacement (LAU)
Battery Positive and Negative Cable Replacement (LAU) |
Removal Procedure |
1. |
Reposition the ECM and the battery cover.
|
2. |
Disconnect the current sensor.
|
3. |
Remove the negative battery cable clamp (1) and the left front radiator support ground terminal (2).
|
4. |
Remove the battery fuse block cover (1).
|
5. |
Remove the battery positive nut (2) from battery fuse block and detach retainer (3) from the battery tray.
|
6. |
Remove the secondary air injection pump. See
Secondary Air Pump, Replacement
|
7. |
Remove the battery positive terminal (4) and nut (1) from the starter solenoid.
|
8. |
Remove the battery negative engine block ground bolt (1) and the harness retainer bolt (2).
|
9. |
Slide the protective boot (2) and remove the generator nut (3) along with the battery positive terminal (4).
|
10. |
Remove the battery positive and negative cable from the vehicle.
|
Installation Procedure |
1. |
Refer to
Fastener Caution
.
Install the battery positive terminal (4) and nut (3) to the back of the generator and tighten to 15 Nm (11 lb ft) . |
2. |
Install the battery positive terminal (4) and nut (1) to the starter motor solenoid and tighten to
15 Nm (11 lb ft)
.
|
3. |
Install the negative battery ground bolt (1) to the engine block and tighten to
45 Nm (33 lb ft)
|
4. |
Refit the secondary air pump attachment bracket on the engine block. See
Secondary Air Pump, Replacement
|
5. |
Install the ground terminal (2) to the left front radiator support and tighten to
25 (18 lb ft)
|
6. |
Install the battery post negative terminal clamp (1) and tighten to
12 Nm (9 lb ft)
.
|
7. |
Install the positive battery cable terminal and nut (2) to the battery fuse block. Tighten to
15 Nm (11 lb ft)
.
|
8. |
Install the battery fuse block cover (1).
|