Liftgate Hydraulic System Bleeding
|
Liftgate Hydraulic System Bleeding
|
Refer to
Eye Protection Warning
.
Note
|
Inspection of the hydraulic fluid level and/or refilling may only be completed if the liftgate hydraulic actuator pump is removed from the vehicle and placed on a clean/level workbench. The liftgate hydraulic actuator pump +- marks must be positioned horizontally before the hydraulic fluid level is inspected and if necessary topped up. The liftgate hydraulic actuator pump must rest in the horizontal position for one minute before the hydraulic fluid level is inspected. The level must be above the + mark after cycling the liftgate 3-5 times.
|
1.
|
Cycle the liftgate 3-5 times to ensure proper fluid level.
|