SAAB WIS ONLINE

Test values and control module connections for Premium/Prestige

Test values and control module connections for Premium/Prestige




Scope

Values and instructions for testing the voltage levels of the control modules are found under the relevant headed sections.

Remember:


• Observe the conditions set for testing and use common sense when assessing the results.

• The test values presented apply when the ignition is in the ON position unless otherwise stated.

• First make sure that the control module is receiving power and that it is grounded.

• Then check all the sensor inputs and signals from other systems.

• Finally, check the control module outputs. Remember that the test values do not indicate whether the module is working.

• If a test value is incorrect, consult the wiring diagram to trace which leads, connectors and components should be checked more thoroughly.

• The specified test values refer to those obtained with calibrated Fluke 88/97.

• Test values in % (+) and ms (+) show the pulse ratio and pulse duration of the signal. A test instrument capable of giving pulse ratio and pulse duration readings should be used. The (+) symbol indicates a positive trigger pulse, TRIG+.



Main unit connections (26-pin)


> = greater than; < = less than; ~ = AC voltage (LP: LOGIC PROBE P = select pulse; p = visible pulses)

Pin No.

Cable colour

Component/

function

In/Out

Test conditions

Across

Test value

See

1



No connection











2

RD/BU

Power supply +15:

In

Ignition ON

2-4

B+



3



No connection











4

BK

Ground:

In



4 - good grounding point.

<0.5V



5

BK/WH

Mute control

Out

The ignition is switched on

8-5

<1 V after approx. 1 sec. B+ for approx. 10 sec.











The ignition is switched off

8-5





6

YE

Telephone mute

In

No telephone call

6-4

4-6 V

Telephone system











Telephone call

6-4

<2 V



7

GN

Trigger voltage:

Out

Main unit on

7-4



8

RD

Power supply +30:

In



8-4

B+





9

BN/RD

Line output, rear right (-)

Out

Music playing

9-4

0-2 V AC. Dependent on volume control. The test reading should vary with the volume of the music.



10

BU

Line output, front right (-)

Out

Music playing

10-4

0-2 V AC. Dependent on volume control. The test reading should vary with the volume of the music.



11

RD/WH

Line output, front left (-)

Out

Music playing

11-4

0-2 V AC. Dependent on volume control. The test reading should vary with the volume of the music.



12

OG/WH

Line output, rear left (-)

Out

Music playing

12-4

0-2 V AC. Dependent on volume control. The test reading should vary with the volume of the music.



13

GY

Line output, rear right (+)

Out

Music playing

13-4

0-2 V AC. Dependent on volume control. The test reading should vary with the volume of the music.



14

RD

Line output, front right (+)

Out

Music playing

14-4

0-2 V AC. Dependent on volume control. The test reading should vary with the volume of the music.



15

BU/WH

Line output, front left (+)

Out

Music playing

15-4

0-2 V AC. Dependent on volume control. The test reading should vary with the volume of the music.



16

YE/WH

Line output, rear left (+)

Out

Music playing

16-4

0-2 V AC. Dependent on volume control. The test reading should vary with the volume of the music.



17

WH

I-BUS (-)

In/Out

Ignition ON

17-4

2-3 V



18

GN

I-BUS (+)

In/Out

Ignition ON

18-4

2-3 V



19



No connection











20

BK

CD changer RH line input (-)

In

Music playing

20-21

0-2 V AC. The test reading should vary with the volume of the music.



21

BN

CD changer RH line input (+)

In

Music playing

21-20

0-2 V AC. The test reading should vary with the volume of the music.



22

BK

Phone line input, ground

In







Telephone system



23

GY/WH

Phone line input, signal

In







Telephone system



24



No connection











25

RD/WH

CD changer LH line input (-)

In

Music playing

25-26

0-2 V AC. The test reading should vary with the volume of the music.



26

BU/WH

CD changer RH line input (+)

In

Music playing

26-25

0-2 V AC. The test reading should vary with the volume of the music.